Dimension Fastscanversus.496 PSL Wafer

Bruker Dimension Fastscan, KLA .496 PSL Wafer, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
OEMBrukerKLA
CategoryMetrology & InspectionMetrology & Inspection
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyBruker DimensionKLA .496 PSL Wafer
Specifications
X-Y scan range35um x 35um typical / 30um minimum[1]—
Z range>/= 3um[2]—
Vertical Noise floor<40pm RMS, sensor in appropriate environment (up to 625Hz)[2]—
X-Y tip-velocity max (1% tracking error)>2mm/sec[2]—
Z tip-velocity max12mm/sec[2]—
X-Y position noise (closed -loop)=0.20nm RMS typical imaging BW (up to 2.5kHz in adaptive)[2]—
Z sensor noise level30pm RMS typical imaging BW (up to 625Hz)[2]—
X-Y flatness (30um range)=3nm[2]—
Integral nonlinearily (X-Y-Z)<0.50%[2]—
ConfigurationSample size/holder:[2]NIST Traceable[4]
Motorized position stageX & Y axis:[2]—
Instrument typeAtomic force microscope (AFM)[2]—
ModelDimension FastScan[3]—
Vertical noise floor< 40 pm RMS, sensor in appropriate environment (up to 625 Hz)[2]—
X-Y tip-velocity max> 2 mm/sec (1% tracking error)[2]—
X-Y position noise= 0.20 nm RMS typical imaging BW (up to 2.5 kHz in adaptive)[2]—
X-Y flatness= 3 nm (30 um range)[2]—
Integral nonlinearity< 0.50% (X-Y-Z)[2]—
Sample size/holder210 mm vacuum chuck for samples; <= 210 mm in diameter; <= 15 mm thick[2]—
Additional sample handling300 mm vacuum chuck; magnet holder[2]—
Microscope optics5 MP digital camera; 130 um to 1040 um viewing area; digital zoom and motorized focus[2]—
Controller/softwareNanoScope V / NanoScope v8.15 and later[2]—
AFM modesStandard, ScanAsyst, Nanomechanical Mapping, TappingMode (air), TappingMode (fluid), PhaseImaging, Contact Mode, Lateral Force Microscopy, Lift Mode, MFM, EFM, Force Spectroscopy, Force Volume[2]—
PurposeScanning probe microscopy of various sample types; equipped with FastScan and ICON scanners[1]—
AFM descriptionCapable of mapping surfaces with nanoscale lateral resolution and sub-nanometer depth resolution[1]—
Scan rate> 125 Hz when surveying a sample; 1-second per image frame in air or fluid[3]—
Sample accessHigh scan rates independent of sample size; large sample access[3]—
Can scan inAir or fluid[3]—
ControllerNanoScope 6 AFM Controller[3]—
Environment drift rateLess than 200 pm per minute of drift rate over hours[3]—
Sample holderOpen-access platform with large- or multiple-sample holders[3]—
AFM ModesStandard[2]—
System Reliability2%[2]—
E-Box03/01/2024[2]—
Z Scanner01/03/2024[2]—
HV Amplifier01/2024[2]—
Stage Controller08/10/2021[2]—
Nanoscope NS5 Controller07/28/2020[2]—
Wafer size—8 inch[4]
Traceability—NIST Traceable[4]
Compatible systems—Capable on Surfscan 6xy0 and SP1[4]
Category—Metrology & Inspection[5]

Plan your fab

Building a Metrology & Inspection process? Get a complete equipment list.

Open the fab equipment planner →
Sources (5)Every fact above is drawn from these public sources
  1. [1]uwaterloo.cauwaterloo.ca
  2. [2]inventory listing
  3. [3]bruker.combruker.com
  4. [4]inventory listing
  5. [5]waferpedia.comwaferpedia.com