Waferpedia

Comparison ledger

0020 Contour ProjectorversusFTIR

OGP 0020 Contour Projector, Perkin Elmer FTIR, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
FTIRPerkin Elmer
OEMOGPPerkin Elmer
CategoryPrecision OpticsPrecision Optics
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyOGP (Optical Gaging Products) 0020 Contour ProjectorPerkin Elmer FTIR
Cited variants—
  • Frontier FTIR[1]
  • Spectrum Two FTIR[2]
  • Spectrum 3 Tri-Range MIR/NIR/FIR Spectrometer[3]
  • Spotlight Aurora FTIR Microscope[3]
  • PerkinElmer Frontier FTIR[1]
  • PerkinElmer Spectrum Two FTIR[2]
  • PerkinElmer Spectrum 3 FTIR[3]
Specifications
Configuration50-60 Cycle[4]—
Voltage115 V[4]—
Spectral range (Frontier)—mid-IR 8300–350 cm⁻¹, far-IR 700–30 cm⁻¹[1]
Best resolution (Frontier)—0.4 cm⁻¹[1]
Spectral range (Spectrum Two)—8300–350 cm⁻¹[2]
Signal-to-noise ratio (Spectrum Two standard LiTaO₃)—9,300:1[2]
Signal-to-noise ratio (Spectrum Two Peltier-stabilized DTGS)—14,500:1[2]
Operating temperature range (Spectrum Two)—5–45 °C[2]
External dimensions (Spectrum Two, Peltier stabilizer, KBr)—15"W x 18"D x 20"H[2]
Detector (Spectrum Two standard)—LiTaO₃ (lithium tantalate) MIR detector[2]
Interferometer (Spectrum Two)—Dynascan fixed mirror-pair interferometer[2]
OpticsGuard (Spectrum Two)—Protects instrument from humidity; long-life desiccant[2]
Atmospheric Vapor Compensation (Spectrum Two)—Real-time compensation for CO₂ and H₂O[2]
Absolute Virtual Instrument (AVI) option (Spectrum Two)—Uses gas phase spectra for accurate calibration and wavenumber standardization[2]
Spectral Range (Mid-IR, Frontier FTIR)—8300–350 cm−1[1]
Spectral Range (Far-IR, Frontier FTIR)—700–30 cm−1[1]
Best Resolution (Frontier FTIR)—0.4 cm−1[1]
Spectral Range (Spectrum Two FTIR)—8300–350 cm−1[2]
Signal-to-Noise Ratio (Standard detector, Spectrum Two)—9,300:1 (LiTaO3)[2]
Signal-to-Noise Ratio (Peltier stabilized detector, Spectrum Two)—14,500:1[2]
Detector (Spectrum Two)—LiTaO3 (lithium tantalate) MIR detector[2]

Plan your fab

Building a Precision Optics process? Get a complete equipment list.

Open the fab equipment planner →
Sources (4)Every fact above is drawn from these public sources
  1. [1]chem.washington.educhem.washington.edu
  2. [2]laboratory-equipment.comlaboratory-equipment.com
  3. [3]perkinelmer.comperkinelmer.com
  4. [4]inventory listing