Waferpedia

Comparison ledger

6890 Gas Chromatographyversus0 500

Agilent 6890 Gas Chromatography, Blue M 0 500, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
0 500Blue M
OEMAgilentBlue M
CategoryThermal / DiffusionThermal / Diffusion
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyAgilent 6890Blue M 0 500
Cited variants—
Specifications
ConfigurationIncludes:[2]—
InjectorSplit-splitless (standard), others available[2]—
Oven temperatureAmbient +4 - 450 'C[2]—
Oven ramps / plateaus6-7[2]—
Carrier gasesHelium, hydrogen, nitrogen, argon[2]—
Electronic pnuematic controlAuto pressure regulation for split/splitless, septum purge[2]—
Carrier gas control modesConstant pressure and flow modes; pressure and flow programmable[2]—
Pressure range0 - 100 psi (standard), 0 - 150 psi (optional) with 0.01 psi resolution, pressure and temperature corrected[2]—
Retention-time lockingRTL ready[2]—
Flow controlCompatible with optional microfluidics controller[2]—
MakeAgilent[2]—
Model6890[2]0 500[4]
Electronic pneumatic controlAuto pressure regulation for split/splitless, septum purge[2]—
Mainframes6890A, 6890A Plus, and 6890N[1]—
Communication6890A uses HPIB (GPIB); 6890A Plus uses HPIB and can be upgraded to LAN; 6890N comes standard with LAN[1]—
EPC architecture13-channel digital EPC[3]—
Pressure accuracy±0.01 psi[3]—
Temperature stability±0.01 °C[3]—
Oven range–60 to 450 °C[3]—
Oven ramp rateUp to 120 °C/min[3]—
Data acquisition rateUp to 100 Hz[3]—
Retention time lockingEnabled for cross-instrument method transfer[3]—
InjectorsSplit-splitless (standard), others available[2]—
Detector optionsFID, uECD, TCD, PID, FPD, NPD, PDD, MSD, Triple Quadrupole TQ Mass Spec[1]—
Injection portsSplit/Splitless Inlet, Cool On-Column Inlet, Purged Packed Inlet, PTV Inlet, Volatiles Interface[1]—
OriginUSA[3]—
Operational age5–7 years[3]—
Warranty6 months[3]—
Regulatory complianceDesigned for GLP/GMP environments with audit-trail-capable data handling[3]—
Software platformOpenLAB CDS ChemStation (legacy-compatible)[3]—
EPC control13-channel digital electronic pressure control (EPC), pressure accuracy ±0.01 psi[3]—
Temperature programOven ramp rate up to 120 C/min, temperature stability ±0.01 C[3]—
Retention Time Locking (RTL)Enabled for cross-instrument method transfer[3]—
Manufacturer—Blue M[4]
Asset number—139866[4]
Last confirm date—September 10, 2025[4]
Equipment type—Oven[4]

Plan your fab

Building a Thermal / Diffusion process? Get a complete equipment list.

Open the fab equipment planner →
Sources (4)Every fact above is drawn from these public sources
  1. [1]aimanalytical.comaimanalytical.com
  2. [2]inventory listing
  3. [3]instrumenthive.cominstrumenthive.com
  4. [4]Equipment inventory listing