Waferpedia

Comparison ledger

TS150versusS-460

MPI TS150, Signatone S-460, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
S-460Signatone
OEMMPISignatone
CategoryTest & ProbeTest & Probe
Wafer size6"6"
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system—Windows
Generation——
FamilyMPI TS150Signatone S-460
Specifications
Maximum independent terminals4 independent terminals plus additional chuck grounding[1]—
Wafer size compatibilityup to 6 inch[1]—
Chuck stageFine-glide chuck stage on highly stable granite base[1]—
X-Y travel range150 mm x 150 mm coarse and 10 mm x 10 mm fine[1]—
OpticsBinocular optics with oculars or microscope view on monitor[1]—
IlluminationSelectable 4 quadrants LED illumination[1]—
Probe positionersTrue X,Y,Z micro-positioners (MPI PM100)[1]—
Probe tipsInterchangeable tungsten contact tips; two different diameters available[1]—
Measurement capabilityDesigned for electrical testing on wafers or chips[1]—
Maximum terminals4 independent terminals + additional chuck grounding[1]—
Chuck compatibilitywafer sizes up to 6 inch, chip or part of wafers[1]—
Stage typeFine-glide chuck stage on highly stable granite base[1]—
X-Y travel range (coarse)150mm x 150mm[1]—
X-Y travel range (fine)10mm x 10mm[1]—
Probe micro-positionersMPI PM100 true X,Y,Z micro-positioners with interchangeable tungsten (W) contact tips (two different diameter available)[1]—
Additional electrical connectionto the chuck for conductive substrates[1]—
DC measurement unitAgilent 4155C Semiconductor Parameter Analyzer with 4x Medium-power SMU, 2xVSU and 2xVMU[1]—
DC voltage and current capability+/- 40 Volts and +/- 100 mA measurement unit (SMU)[1]—
DC measurement resolution10 femtoamp and 0.2 microvolt[1]—
Switching box configurations6 configuration options for standard applications such as FET, bipolar transistors, diodes, 2-points and 4-points general measurements[1]—
DC softwareDesktop EasyEXPERT software for PC-based GUI instrument control[1]—
AC measurement unitZürich Instruments MFIA multi-frequency impedance analyzer[1]—
AC signal frequencyDC to 5 MHz[1]—
AC signal voltage0 to 2.1 V RMS[1]—
DC bias (2 probes)+/- 10 Volts[1]—
DC bias (4 probes)+/- 3 Volts[1]—
Impedance range1 mOhm to 1 TOhm[1]—
AC test fixtureMFITF can be mounted on the MFIA for rapid testing of wire-bonded surface-mounted devices[1]—
AC softwareLabOne software for PC-based GUI instrument control[1]—
Maximum wafer size compatibilityup to 6 inch[1]—
Number of independent terminalsmaximum 4 plus additional chuck grounding[1]—
DC voltage range+/-40 Volts[1]—
DC current range+/-100 mA[1]—
SMU measurement resolution10 femtoamp and 0.2 microvolt[1]—
AC signal frequency rangeDC to 5 MHz[1]—
AC signal voltage range0 to 2.1 V RMS[1]—
DC bias range (2 probes)+/-10 Volts[1]—
DC bias range (4 probes)+/-3 Volts[1]—
Impedance range (AC)1 mOhm to 1 TOhm[1]—
Probe micro-positioner modelMPI PM100[1]—
Probe tip materialtungsten carbide (W)[1]—
TypeProbe station[1]—
UseElectrical testing on wafers or chips[1]—
Maximum wafer sizeup to 6 inch[1]—
Independent terminalsmaximum of 4 independent terminals + additional chuck grounding[1]—
Probe positioningThree-axis movement of the probe tips with manual micro-manipulators[1]—
Chuck travel range150 mm x 150 mm coarse and 10 mm x 10 mm fine X-Y travel range[1]—
Max independent terminals4 plus additional chuck grounding[1]—
DC measurement voltage+/- 40 Volts[1]—
DC measurement current+/- 100 mA[1]—
DC measurement resolution (current)10 femtoamp[1]—
DC measurement resolution (voltage)0.2 microvolt[1]—
AC DC bias (2 probes)+/- 10 Volts[1]—
AC DC bias (4 probes)+/- 3 Volts[1]—
Probe station type—Semi-automatic probe station[2]
Wafer size—6"[2]
Wafer stage drive—Proprietary linear induction motor[2]
Positioning system—Optical feedback positioning system[2]
Wafer stepping—Automated wafer stepping controlled via Signatone Solutions Windows software[2]
Theta—Motorized theta with a quick two-point align feature[2]
Control era—Windows[3]

Plan your fab

Building a Test & Probe process? Get a complete equipment list.

Open the fab equipment planner →
Sources (3)Every fact above is drawn from these public sources
  1. [1]epfl.chepfl.ch
  2. [2]web.archive.orgweb.archive.org
  3. [3]waferpedia.comwaferpedia.com