The Agilent N5230A is a vector network analyzer from the PNA-L series of microwave network analyzers. The N5230A is manufactured by Agilent Technologies. The N5230A is offered in two-port and four-port configurations. The two-port configuration spans frequency ranges from 10 MHz to 20, 40, or 50 GHz. The four-port configuration spans frequency ranges from 300 kHz to 13.5 or 20 GHz.[1][2][3][4][5][6]
The N5230A performs error correction through calibration. Calibration is the process of measuring known standards to characterize systematic errors. The N5230A supports calibration using mechanical calibration kits such as the 85052B and 85056A and electronic calibration modules such as the N4691A, N4693A, and N4433A. The corrected system performance specifications are determined by the quality of calibration standards, system repeatability, stability, and noise. The N5230A also provides uncorrected system performance specifications for measurements without error correction.[3][4][5][6]
The N5230A is a two-port or four-port network analyzer, so it can measure one-port and two-port devices and, in the four-port configuration, multi-port devices. The four-port configurations cover 300 kHz to 13.5 or 20 GHz. The four-port configurations with options 146 and 246 include an internal second source. Four-port measurement capability allows characterization of differential and balanced devices. The two-port configurations cover 10 MHz to 20, 40, or 50 GHz.[4][3]
The N5230A's performance specifications are defined for measurements over a temperature range of 25 °C ±5 °C, after a warm-up time of 90 minutes. The instrument provides specified dynamic range across its frequency bands. For example, the two-port system with configurable test set and extended power range specifies a system dynamic range of 95 dB at 31.25 GHz to 40 GHz and 79 dB at 40 GHz to 50 GHz. The four-port system specifies a system dynamic range of 103 dB at 15 GHz to 20 GHz for the standard configuration. The N5230A supports measurements with a 10 Hz IF bandwidth and no averaging for the corrected system performance specifications. The instrument includes a segment sweep mode that allows predefined frequency segments at different power levels.[3][4]
| Designation | Generation | Vintage | Changes | Source |
|---|---|---|---|---|
| N5230A Option 220 | — | — | Standard test set and standard power range. | aaatesters.com[3] |
| N5230A Option 225 | — | — | Configurable test set and extended power range. | aaatesters.com[3] |
| N5230A Option 240 | — | — | Standard test set and standard power range. | assets-us-01.kc-usercontent.com[4] |
| N5230A Option 245 | — | — | Configurable test set and extended power range. | assets-us-01.kc-usercontent.com[4] |
| N5230A Option 246 | — | — | Configurable test set, extended power range, and internal second source. | assets-us-01.kc-usercontent.com[4] |
Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.
Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.
No research found yet — worked with this tool? Share what you know.
The two-port configuration covers 10 MHz to 20, 40, or 50 GHz. The four-port configuration covers 300 kHz to 13.5 or 20 GHz.[2][3][4]
The N5230A supports mechanical calibration kits such as the 85052B and 85056A, and electronic calibration modules such as the N4691A, N4693A, and N4433A.[2][3][4]
Specifications apply after a warm-up time of 90 minutes.[3][4][5]
The specifications are given for a 10 Hz IF bandwidth with no averaging.[3][4]
Yes, the N5230A includes a segment sweep mode that allows predefined frequency segments at different power levels.[4]
The following facts about the N 5230 A Vector Network Analyzer are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.
No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the N 5230 A Vector Network Analyzer are on record.
Answerable by: OEM historical records or a trade-press announcement
The control-system platform and OS era of the N 5230 A Vector Network Analyzer are not on record.
Answerable by: an engineer who operated it or OEM installation records
No publicly documented failure modes or field errata for the N 5230 A Vector Network Analyzer are on record.
Answerable by: a field service engineer, process engineer, or maintenance technician
The process node or technology generation of the N 5230 A Vector Network Analyzer is not on record.
Answerable by: an OEM datasheet or a fab qualification report
No publicly documented compatible parts, consumables, or accessories for the N 5230 A Vector Network Analyzer are on record.
Answerable by: an OEM parts catalog or a service engineer
No research found yet — worked with this tool? Share what you know.
Last updated Oct 11, 2026.
The ABM-407B-2-S-CE-S293 is a robot.