Waferpedia

Applied Materials

Centura AP AdvantEdge G 5 Dry

EtchApplied Materials Centura family
Research Quality: 50% complete
Centura AP AdvantEdge G 5 Dry — Inventory photo
Fig. 01Centura AP AdvantEdge G 5 DryInventory photo[1]

Power

3 Phase[1]

Gas delivery

N2, O2, CF4[1]

What it is

The Applied Materials Centura AP AdvantEdge G 5 Dry is a dry etcher for semiconductor manufacturing.[1]

The Applied Materials Centura AP AdvantEdge G 5 Dry uses a standard loadport and a Server GEM II interface.[1]

How it works

General reference — not yet source-verified

A dry etcher removes patterned material from a wafer by exposing selected areas to reactive process gases in a controlled plasma-based etch environment.

A dry etcher is used with separate process chambers that can be configured for different gas chemistries and etch steps.

Where it fits in the process flow

General reference — not yet source-verified

A dry etcher sits in the pattern transfer portion of semiconductor fabrication after lithography has defined the pattern to be etched.

A dry etcher is followed by downstream cleaning, inspection, and later process steps that depend on the etched topography.

Applications

General reference — not yet source-verified

The Applied Materials Centura AP AdvantEdge G 5 Dry is a semiconductor dry etch tool used for pattern transfer on processed wafers.

What do the numbers mean?

Power & electrical4

Phase
3 Phase[1]
Accurate?
50/60 Hz[1]
Accurate?
Electrical
3 Phase - 3 Wire[1]
Accurate?
Frequency
50/60 Hz[1]
Accurate?

Gas & chemistry6

Chamber A Chemicals Gases Used
BCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
Accurate?
Chamber B Chemicals Gases Used
BCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
Accurate?
Chamber D Chemicals Gases Used
N2, O2, CF4[1]
Accurate?
Chamber A gases
BCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
Accurate?
Chamber B gases
BCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
Accurate?
Chamber D gases
N2, O2, CF4[1]
Accurate?

Control & software1

Control system
Server GEM II[1]
Accurate?

Configuration & options12

3 Wire + G Line[1]
Accurate?
Standard Loadport[1]
Accurate?
Server GEM II[1]
Accurate?
Chamber D-strip chamber[1]
Accurate?
No HDD[1]
Accurate?
OEM
Applied Materials[1]
Accurate?
Model
Centura AP AdvantEdge G 5[1]
Accurate?
Equipment type
Dry Etcher[1]
Accurate?
Line
G Line[1]
Accurate?
Loadport
Standard Loadport[1]
Accurate?
HDD
No HDD[1]
Accurate?
Vintage
2013[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Phase3 Phase[1]
  • Configuration50/60 Hz[1]
  • Chamber A Chemicals Gases UsedBCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
  • Chamber B Chemicals Gases UsedBCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
  • Chamber D Chemicals Gases UsedN2, O2, CF4[1]
  • Electrical3 Phase - 3 Wire[1]
  • Frequency50/60 Hz[1]
  • Chamber A gasesBCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
  • Chamber B gasesBCl3, Cl2, SO2, NF3, CH2F2, HBr, O2, N2, CF4, He, CHF3, SF6, Ar[1]
  • Chamber D gasesN2, O2, CF4[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of equipment is the Applied Materials Centura AP AdvantEdge G 5 Dry?

The Applied Materials Centura AP AdvantEdge G 5 Dry is a dry etcher.[1]

What interface does this tool use?

The Applied Materials Centura AP AdvantEdge G 5 Dry uses a Server GEM II interface.[1]

What loadport configuration is specified for this tool?

The Applied Materials Centura AP AdvantEdge G 5 Dry uses a standard loadport.[1]

Does the tool have an HDD?

The Applied Materials Centura AP AdvantEdge G 5 Dry has no HDD.[1]

Not publicly documented

The following facts about the Centura AP AdvantEdge G 5 Dry are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Centura AP AdvantEdge G 5 Dry are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Centura AP AdvantEdge G 5 Dry are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Centura AP AdvantEdge G 5 Dry are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Centura AP AdvantEdge G 5 Dry are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Centura AP AdvantEdge G 5 Dry is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]Inventory photo
Was this page accurate?

Last updated Oct 6, 2026.

Compare with similar tools