Waferpedia

Bruker

Dektak 150

Metrology & InspectionBruker Dektak family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Bruker Dektak 150 is a surface texture measuring system that uses a diamond-tipped stylus for electromechanical measurements. The Dektak 150 can measure film thickness up to 1000 μm and has a vertical resolution of 1 Å.[1]

Dektak 150 — Inventory photo
Fig. 01Dektak 150Inventory photo[2]

Performance

6Å, 1 sigma on 1μm step[1]

Optics

1Å max. (at 6.55μm range)[1]

How it works

Measurements are made electromechanically by moving the sample beneath a diamond-tipped stylus according to a user-programmed scan length, speed and stylus force. As the stylus moves across the sample, surface variations cause it to be translated vertically, generating an electrical signal that corresponds to step height. The system features a computer interface (Windows XP environment) and a Y automatic stage with 100mm travel, 1μm repeatability, and 0.5μm resolution. Stylus radius options range from 50nm to 25μm. A 640 x 480-pixel camera with manual zoom (variable 0.67 to 4.29mm) aids in positioning. The system can perform small-scale 3-D sample mapping using the Y-axis stage motor control.[1]

Why won't it start?

Documented failure modes, common issues, and field considerations.

  • for parts

What do the numbers mean?

Optics & imaging5

Vertical Resolution
1Å max. (at 6.55μm range)[1]
Accurate?
Stage Resolution
0.5μm[1]
Accurate?
Camera
640 x 480-pixel, manual zoom variable 0.67 to 4.29mm (644X to 100X with 17in. monitor)[1]
Accurate?
Y automatic stage travel
100mm (4 inches), 1μm repeatability, 0.5μm resolution[1]
Accurate?
Camera
640 x 480-pixel (1/3in.-format) with manual zoom, variable 0.67 to 4.29mm (644X to 100X with 17in. monitor)[1]
Accurate?

Performance2

Step Height Repeatability
6Å, 1 sigma on 1μm step[1]
Accurate?
Stage Repeatability
1μm[1]
Accurate?

Configuration & options12

for parts[4]
Accurate?
Scan Length
55mm (2.16in.)[1]
Accurate?
Data Points Per Scan
60,000 maximum[1]
Accurate?
Max Sample Thickness
Up to 100mm (4in.)[1]
Accurate?
Max Sample Size
150mm (6in.)[1]
Accurate?
Stage Travel
100mm (4 inches)[1]
Accurate?
Stylus Radius Options
from 50nm to 25μm[1]
Accurate?
Maximum scan length
55mm (2.16in.)[1]
Accurate?
Maximum data points per scan
60,000[1]
Accurate?
Maximum sample thickness
Up to 100mm (4in.)[1]
Accurate?
Maximum sample size
150mm (6in.)[1]
Accurate?
Film thickness measurement range
up to 1000μm[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the scan length of the Dektak 150?

The scan length is 55 mm (2.16 in).[1]

What is the maximum sample size the Dektak 150 can accommodate?

The maximum sample size is 150 mm (6 in).[1]

What is the step height repeatability of the Dektak 150?

Step height repeatability is 6 Å, 1 sigma on a 1 μm step.[1]

What is the vertical resolution of the Dektak 150?

Vertical resolution is 1 Å maximum (at 6.55 μm range).[1]

What is the maximum film thickness the Dektak 150 can measure?

Film thickness measurements up to 1000 μm are supported.[1]

What is the measurement principle of the Dektak 150?

Measurements are made electromechanically by moving the sample beneath a diamond-tipped stylus; vertical stylus displacement produces an electrical signal representing step height.[1]

Not publicly documented

The following facts about the Dektak 150 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Dektak 150 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Dektak 150 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Dektak 150 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • The process node or technology generation of the Dektak 150 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Dektak 150 are on record.

    Answerable by: an OEM parts catalog or a service engineer

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]smif.pratt.duke.edu — smif.pratt.duke.edusmif.pratt.duke.edu
  2. [2]Inventory photo
  3. [3]Inventory photo
  4. [4]Inventory photo
  5. [5]Equipment inventory listing
Was this page accurate?

Last updated Sep 29, 2026.

Compare with similar tools

View all →