Waferpedia

Exatron

902

Test & ProbeExatron 902 family
Research Quality: 40% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Exatron Model 902 is a pick-and-place IC handler offered in Random Sort and Burn-in Board Transfer configurations. The Model 902 Random Sort IC Handler identifies and sorts assorted bulk devices to output tape or tray, best suited for devices 0.5mm x 0.5mm to 2.0mm x 2.0mm. The Model 902 Burn-in Board Transfer IC Handler transfers devices from JEDEC trays to burn-in boards and back again, based on the Exatron Model 900.[1][2]

902 — Inventory photo
Fig. 01902Inventory photo[3]

Power

100-240VAC 50/60Hz @ 240 Watts[1]

Vacuum

5.9 bar (85 PSI) @ 3 CFM clean, dry air[1]

Performance

±0.1mm (0.003")[1]

Optics

0.1mm (0.003")[1]

What it is

The Exatron 902 is a series of pick-and-place IC handlers used in semiconductor test and packaging operations. The series includes the Model 902 Random Sort IC Handler and the Model 902 Burn-in Board Transfer IC Handler. The 902 is based on the Exatron Model 900 platform. The system is designed, manufactured, and built in San Jose, California.[1][2]

How it works

The Exatron 902 uses an X-Y positioning system driven by servo motor–driven lead screws. The X-Y axis resolution is 0.1 mm (0.003 inch). The maximum X-Y axis velocity is 122 cm/s (48 inches per second). The Z-axis plunger is driven by a servo motor and lead screw with a resolution of ±0.1 mm and a repeatability of ±0.1 mm. The placement force is up to 10 kg (20 lb). The theta drive system uses precision stepper motors with a resolution of 0.1° and a repeatability of ±0.1 mm.[1][2]

What do the numbers mean?

Power & electrical1

Power
100-240VAC 50/60Hz @ 240 Watts[1]
Accurate?

Vacuum & pumping1

Air
5.9 bar (85 PSI) @ 3 CFM clean, dry air[1]
Accurate?

Optics & imaging3

X-Y Axis Resolution
0.1mm (0.003")[1]
Accurate?
Z Axis Resolution
±0.1mm (0.003")[1]
Accurate?
Theta Axis Resolution
0.1°[1]
Accurate?

Performance2

Z Axis Repeatability
±0.1mm (0.003")[1]
Accurate?
Theta Axis Repeatability
±0.1mm (0.003")[1]
Accurate?

Configuration & options5

Device size range (Random Sort)
0.5mm x 0.5mm – 2.0mm x 2.0mm[1]
Accurate?
X-Y Axis Max. Velocity
122cm/s (48"/s)[1]
Accurate?
Placement Force
Up to 10kg (20lbs) force with standard pickup heads[1]
Accurate?
Operational Temp.
13-32°C (55-90°F)[1]
Accurate?
Humidity
35-90% RH non-condensing[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
Model 902 Random Sort IC Handler——Identifies and sorts assorted bulk devices to output tape or tray; best suited for devices 0.5mm x 0.5mm – 2.0mm x 2.0mm; Windows 10-based GUI.exatron.com[1]
Model 902 Burn-in Board Transfer IC Handler——Transfers devices from JEDEC trays to burn-in boards and back; features a pickup head that opens/closes sockets; Windows 11 operator GUI; based on the Exatron Model 900.exatron.com[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power100-240VAC 50/60Hz @ 240 Watts[1]
  • Air5.9 bar (85 PSI) @ 3 CFM clean, dry air[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the X-Y axis resolution of the Exatron 902?

The X-Y axis resolution is 0.1 mm (0.003 inch).[1][2]

What are the power requirements for the Exatron 902?

The power requirement is 100–240 VAC, 50/60 Hz, at 240 watts.[1][2]

What are the air supply requirements for the Exatron 902?

The air supply requirement is 5.9 bar (85 PSI) at 3 CFM of clean, dry air.[1][2]

What vision options are available on the Exatron 902?

Vision options include device presence and Pin 1 rotation inspection, and on the Burn-in Board transfer variant, a BIB 1D/2D bar code reader and ID software.[1][2]

Not publicly documented

The following facts about the 902 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the 902 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the 902 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the 902 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the 902 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the 902 are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]exatron.com — exatron.comexatron.com
  2. [2]exatron.com — exatron.comexatron.com
  3. [3]Inventory photo
Was this page accurate?