The JDSU SC Series is a programmable fiberoptic switch. The JDSU SC Series is a 1xN switch that connects a single fiberoptic input channel to any of up to 180 output channels. The JDSU SC Series is available in single-mode and multimode versions.[1][2]

SC Series — Inventory photo
Fig. 01SC SeriesInventory photo[3]

Power

110/115/230/240V AC, 50 to 60 Hz[1]

Performance

0.003 dB[1]

Optics

Programmable fiberoptic switch[1]

What it is

The JDSU SC Series is a programmable fiberoptic switch. The SC Series is a fiberoptic switch product line from JDSU.[1]

The SC Series is categorized as test and probe equipment in semiconductor and photonics manufacturing contexts. The SC Series is a tester.[2][3]

How it works

The SC Series switch routes optical signals between its input and output fiber ports under electronic control. The switch uses a GPIB or RS232 interface for remote control and can be operated locally from its front-panel keys.[1]

The SC Series has several configuration variants: the single-common (SC-C), dual-common (SC-D), single-step dual-common (SC-E), and dual-common blocking (SC-F) configurations.[1]

Applications

The SC Series is used in fiberoptic component testing and system verification. The switch supports automated test sequences that require switching among multiple optical paths.[1]

What do the numbers mean?

Power & electrical1

Input voltage
110/115/230/240V AC, 50 to 60 Hz[1]
Accurate?

Optics & imaging2

Type
Programmable fiberoptic switch[1]2 sources
Accurate?
Applications
Fiberoptic component testing, transmitter/receiver measurement, research and development[1]
Accurate?

Performance1

Typical repeatability
0.003 dB[1]2 sources
Accurate?

Control & software1

Interfaces
IEEE 488.1 parallel interface and RS232C serial interface[1]
Accurate?

Dimensions & facilities1

Weight
Single-height 9 kg; double-height 14 kg[1]
Accurate?

Configuration & options12

Architecture
1xN switch[1]2 sources
Accurate?
Channel capacity
Up to 180 output channels[1]2 sources
Accurate?
Versions
Single-mode and multimode versions available[1]2 sources
Accurate?
Typical insertion loss
0.4 dB[1]2 sources
Accurate?
Typical return loss
Greater than 65 dB[1]2 sources
Accurate?
RS232 data protocol
1200 baud, ASCII, 8 bits per character, 1 stop bit, no parity[1]
Accurate?
Drivers
Eight open collector outputs[1]
Accurate?
Driver current
100 mA maximum per output[1]
Accurate?
Power consumption
100 VA maximum[1]
Accurate?
Operating temperature
0 to 55 °C[1]
Accurate?
Storage temperature
-40 to 70 °C[1]
Accurate?
Humidity
Maximum 95% RH from 0 to 55 °C[1]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
SC-C——Single-common configuration.viavisolutions.com[1]
SC-D——Dual-common configuration.viavisolutions.com[1]
SC-E——Single-step dual-common configuration.viavisolutions.com[1]
SC-F——Dual-common blocking configuration.viavisolutions.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Input voltage110/115/230/240V AC, 50 to 60 Hz[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What kind of measurements can be performed?General reference — not yet source-verified

Typical measurements include I-V and C-V curves, leakage current, threshold voltage, on-resistance, breakdown voltage, photoresponsivity, spectral response, and optical coupling efficiency. The actual measurement capabilities depend on the external instruments connected to the probe system, such as source measure units (SMUs), lock-in amplifiers, or optical spectrum analyzers.

Not publicly documented

The following facts about the SC Series are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the SC Series are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the SC Series are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the SC Series are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the SC Series is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the SC Series are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]viavisolutions.com — viavisolutions.comviavisolutions.com
  2. [2]SC Series — JDSU | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
  3. [3]Inventory photo
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →