Waferpedia

Leybold

IBS 1400 HT GT Dual Ion Beam

The Leybold IBS 1400 HT GT is a dual ion beam sputtering system for deposition. The IBS 1400 HT GT includes a 4-position target tower with 3 target positions (optional 4th target). The IBS 1400 HT GT has a main KRI sputter source and an additional KRI assist source.[1][2]

IBS 1400 HT GT Dual Ion Beam — Inventory photo
Fig. 01IBS 1400 HT GT Dual Ion BeamInventory photo[1]

What it is

The Leybold IBS 1400 HT GT Dual Ion Beam is a dual ion beam sputtering system for deposition.[1][2]

The IBS 1400 HT GT includes a four-position target tower with three target positions and an optional fourth target, a main KRI sputter source, an additional KRI assist source, an OMS5100i direct optical monitor, a planetary substrate carrier, a ceramic plate substrate heater, and front and rear doors.[1][2]

How it works

The IBS 1400 HT GT uses a main KRI sputter source and an additional KRI assist source.[1][2]

The IBS 1400 HT GT uses a 4 x 350 mm planetary substrate carrier, and two 530 mm planets can also be installed.[1][2]

Where it fits in the process flow

The IBS 1400 HT GT includes an optical monitor and test glasses with shutters for complex process monitoring schemes.[1][2]

Applications

The IBS 1400 HT GT includes a ceramic plate substrate heater and an OMS5100i direct optical monitor.[1][2]

What do the numbers mean?

Wafer handling6

4 x 35 0mm planetary substrate carrier (2 x 530 mm planets can also be installed)[1]
Accurate?
Two test glasses (with shutter) on the substrate carrier for complex process monitoring schemes[1]
Accurate?
Ceramic plate substrate heater[1]
Accurate?
Substrate carrier
4 x 350mm planetary substrate carrier (2 x 530 mm planets can also be installed)[2]
Accurate?
Test glasses
Two test glasses (with shutter) on the substrate carrier for complex process monitoring schemes[2]
Accurate?
Substrate heater
Ceramic plate substrate heater[2]
Accurate?

Optics & imaging2

OMS5100i direct optical monitor (as installed in the HELIOS)[1]
Accurate?
Optical monitor
OMS5100i direct optical monitor (as installed in the HELIOS)[2]
Accurate?

Configuration & options8

4 position target tower with 3 target positions (optional 4th target)[1]
Accurate?
Main KRI sputter source and additional KRI assist source[1]
Accurate?
Front and rear doors[1]
Accurate?
Target tower positions
4 position target tower with 3 target positions (optional 4th target)[1]
Accurate?
Sputter source
Main KRI sputter source and additional KRI assist source[2]
Accurate?
Doors
Front and rear doors[2]
Accurate?
Process type
Dual ion beam sputtering system for deposition[2]
Accurate?
Target tower
4-position target tower with 3 target positions (optional 4th target)[2]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What type of ion sources does the Leybold IBS 1400 HT GT use?

The system uses KRI sputter and assist sources.[1]

What substrate carrier options are available?

The system has a four-position planetary substrate carrier with 350 mm positions. Two 530 mm planets can also be installed.[1]

Does the system include optical monitoring?

Yes, it includes an OMS5100i direct optical monitor.[1]

Does the system have substrate heating?

Yes, it includes a ceramic plate substrate heater.[1]

Not publicly documented

The following facts about the IBS 1400 HT GT Dual Ion Beam are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the IBS 1400 HT GT Dual Ion Beam are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the IBS 1400 HT GT Dual Ion Beam are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the IBS 1400 HT GT Dual Ion Beam are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the IBS 1400 HT GT Dual Ion Beam are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the IBS 1400 HT GT Dual Ion Beam is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Inventory photo
  2. [2]waferpedia.com — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 13, 2026.

Compare with similar tools

View all →