Power

480 m3/h; 8,000 l/mn; 282 cfm[2]

Vacuum

Pump[1]

What it is

The Pfeiffer Alcatel ADS 602 P is a dry pump vacuum system.[1][2]

Applications

The ADS 602 P is used as a process-duty dry pump vacuum system.[2]

What do the numbers mean?

Power & electrical9

Nominal flow-rate at 50 Hz (w/o Conv.)
480 m3/h; 8,000 l/mn; 282 cfm[2]
Accurate?
Nominal flow-rate at 50 Hz (w/ Conv.)
560 m3/h; 8,000 l/mn; 329 cfm[2]
Accurate?
Nominal flow-rate at 60 Hz (w/o Conv.)
560 m3/h; 9,333 l/mn; 329 cfm[2]
Accurate?
Nominal flow-rate at 60 Hz (w/ Conv.)
580 m3/h; 9,667 l/mn; 341 cfm[2]
Accurate?
Ultimate pressure at 50 Hz
8 x 10 -4 mbar; 6 x 10 -4 Torr[2]
Accurate?
Ultimate pressure at 60 Hz
5 x 10 -4 mbar; 3.7 x 10 -4 Torr[2]
Accurate?
Nominal power
3 kW[2]
Accurate?
Supply voltage
3 Ph 200 / 480 V[2]
Accurate?
Consumption at ultimate pressure
50 Hz: 1.8 kW; 60 Hz: 2.0 kW[2]
Accurate?

Vacuum & pumping5

Equipment type
Pump[1]
Accurate?
Description
Dry Pump Vacuum System - REBUILT[2]
Accurate?
Max. continuous inlet pressure
10 mbar[2]
Accurate?
Pump running ambient temp.
5 to 40°C[2]
Accurate?
Inlet/Exhaust port
DN 100 ISO-K / DN 40 ISO-KF[2]
Accurate?

Dimensions & facilities4

Cooling water
60 l/h[2]
Accurate?
Dimensions
32.7 x 15.4 x 34.4 inches[2]
Accurate?
Weight
400 kg[2]
Accurate?
Weight
900 lbs[2]
Accurate?

Configuration & options5

OEM
Pfeiffer / Alcatel[1]
Accurate?
Model
ADS 602 P[1]
Accurate?
Model designation
602P (Process Duty)[2]
Accurate?
N2 purge flow rate
0 to 50 sl/mn[2]
Accurate?
Rotation speed
3,000 to 3,600 rpm[2]
Accurate?

Vintage & configurations

Documented models & variants

DesignationGenerationVintageChangesSource
602LM——Light to Medium Dutyptbsales.com[2]
602P——Process Dutyptbsales.com[2]
602H——Harsh Dutyptbsales.com[2]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Equipment typePump[1]
  • DescriptionDry Pump Vacuum System - REBUILT[2]
  • Nominal flow-rate at 50 Hz (w/o Conv.)480 m3/h; 8,000 l/mn; 282 cfm[2]
  • Nominal flow-rate at 50 Hz (w/ Conv.)560 m3/h; 8,000 l/mn; 329 cfm[2]
  • Nominal flow-rate at 60 Hz (w/o Conv.)560 m3/h; 9,333 l/mn; 329 cfm[2]
  • Nominal flow-rate at 60 Hz (w/ Conv.)580 m3/h; 9,667 l/mn; 341 cfm[2]
  • Ultimate pressure at 50 Hz8 x 10 -4 mbar; 6 x 10 -4 Torr[2]
  • Ultimate pressure at 60 Hz5 x 10 -4 mbar; 3.7 x 10 -4 Torr[2]
  • Nominal power3 kW[2]
  • Supply voltage3 Ph 200 / 480 V[2]
  • Consumption at ultimate pressure50 Hz: 1.8 kW; 60 Hz: 2.0 kW[2]
  • Max. continuous inlet pressure10 mbar[2]
  • Pump running ambient temp.5 to 40°C[2]
  • Inlet/Exhaust portDN 100 ISO-K / DN 40 ISO-KF[2]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What duty class is the ADS 602 P?

The ADS 602 P is the process-duty variant in the ADS 602 family.[2]

What product family does the ADS 602 P belong to?

The ADS 602 P belongs to the Adixen Alcatel ADS package family.[2]

Not publicly documented

The following facts about the Alcatel ADS 602 P are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Alcatel ADS 602 P are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • The control-system platform and OS era of the Alcatel ADS 602 P are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Alcatel ADS 602 P are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Alcatel ADS 602 P is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Alcatel ADS 602 P are on record.

    Answerable by: an OEM parts catalog or a service engineer

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]Equipment inventory listing
  2. [2]ptbsales.com — ptbsales.comptbsales.com
Was this page accurate?

Last updated Oct 8, 2026.

Compare with similar tools

View all →