What it is

The Signatone S-302-4 includes a 100 mm probe stand and a four-point probe head with 5 mil radius tips spaced at 40 mil intervals. The S-302-4 is used to make sheet resistance and resistivity measurements of substrates and thin films. The S-302-4 interfaces with a Keithley 2450 SourceMeter to perform these measurements. The S-302-4 is part of a probe station system that also includes a Cascade MicroTech EPS150TRIAX probe station.[1][2][3]

How it works

The S-302-4 operates by lowering the four-point probe head into contact with the sample using a lever arm. The probe tips are compressed between 50% and 70% of their travel during contact. The probe height can be adjusted using a Z-adjust knob. Current is sourced through the outer probes and the voltage is measured across the inner probes, allowing calculation of sheet resistance using a correction factor that accounts for sample geometry.[3]

The S-302-4 is used with Keithley KickStart software for measurement control and data export. Measurements can be performed in two-wire or four-wire configurations. The Keithley 2450 provides voltage and current sourcing and measurement capability.[1]

Where it fits in the process flow

General reference — not yet source-verified

The S-302-4 is used for ex situ characterization of thin films and substrates in a laboratory or cleanroom environment. Sheet resistance and resistivity measurements are performed after film deposition or substrate preparation to evaluate electrical properties. The tool is typically employed during process development, quality control, and research investigations rather than in-line production wafer mapping.

Applications

The S-302-4 is used for sheet resistance and resistivity measurements of substrates and thin films. Applications include I-V characterization, low-current measurements, C-V characterization, and resistance and conductance measurements. The tool is suitable for measuring the sheet resistance of conductive inks, transparent conductive oxides, metal films, and other thin-film materials.[1][4][5]

  • Sheet resistance measurements
  • Resistivity measurements of substrates
  • Resistivity measurements of thin films

What do the numbers mean?

Wafer handling2

Measurement use
Sheet resistance and resistivity measurements of substrates and thin films[1]
Accurate?
Measurement capabilities
Sheet resistance and resistivity measurements of substrates and thin films[1]
Accurate?

Control & software2

Interfaces with
Keithley 2450[1]
Accurate?
Interfaces
Keithley 2450[1]
Accurate?

Configuration & options4

Type
Four Point Resistivity Probe Station[1]2 sources
Accurate?
Probe stand
100 mm[1]
Accurate?
Probe head
4 point probe head with 5 mil radius tips of 40 mil spacing[1]
Accurate?
Probe stand size
100 mm[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What replaced it?

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the probe tip spacing of the S-302-4?

The probe tip spacing is 40 mil (0.040 inches).[2]

What is the probe tip radius of the S-302-4?

The probe tip radius is 5 mil (0.005 inches).[2]

What is the wafer size capacity of the S-302-4?

The S-302-4 has a 100 mm probe stand, accommodating samples up to 100 mm in diameter.[1][2]

What instrument does the S-302-4 interface with for measurements?

The S-302-4 interfaces with a Keithley 2450 SourceMeter for current sourcing and voltage measurement.[1][3]

What types of measurements can the S-302-4 perform?

The S-302-4 is used for sheet resistance and resistivity measurements of substrates and thin films.[1][6]

Not publicly documented

The following facts about the S-302-4 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the S-302-4 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the S-302-4 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the S-302-4 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the S-302-4 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the S-302-4 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (6)Every fact above is drawn from these public sources
  1. [1]smif.pratt.duke.edu — smif.pratt.duke.edusmif.pratt.duke.edu
  2. [2]S-302-4 — Signatone | Specs, Sourcing & Service | Waferpedia — waferpedia.comwaferpedia.com
  3. [3]https://smif.pratt.duke.edu/sites/smif.pratt.duke.edu/files/2023/PROBE2%20Operating%20Procedure%20Rev-2023-06.pdf — smif.pratt.duke.edusmif.pratt.duke.edu
  4. [4]https://arc.lib.montana.edu/ojs/index.php/IJS/article/download/3427/3072 — arc.lib.montana.eduarc.lib.montana.edu
  5. [5]https://li01.tci-thaijo.org/index.php/anres/article/download/243422/166125 — li01.tci-thaijo.orgli01.tci-thaijo.org
  6. [6]Signatone S-302-4 family | Waferpedia — waferpedia.comwaferpedia.com
Was this page accurate?

Last updated Oct 9, 2026.

Compare with similar tools

View all →