Waferpedia

SPTS

Monarch Hydrofluoric (HF) Vapor

The SPTS / STS Monarch is a hydrofluoric (HF) vapor etcher for 8-inch wafers. The Monarch operates at a temperature range of 35°C to 70°C and a pressure range of 50–250 Torr. The Monarch supports HF flow rates from 50 to 1000 sccm and ethanol flow rates from 0.1 to 1 ml/min.[1]

Monarch Hydrofluoric (HF) Vapor — Inventory photo
Fig. 01Monarch Hydrofluoric (HF) VaporInventory photo[1]

Vacuum

50-250 Torr[1]

Gas delivery

50 sccm-1000 sccm[1]

What it is

The SPTS Monarch is a single-wafer vapor-phase hydrofluoric (HF) etcher designed for processing 200 mm (8-inch) wafers. The tool operates with a specified temperature range of 35 °C to 70 °C, a chamber pressure range of 50 Torr to 250 Torr, HF flow rates from 50 sccm to 1000 sccm, and ethanol flow rates from 0.1 ml/min to 1 ml/min.[1]

How it works

General reference — not yet source-verified

Vapor HF etching uses anhydrous HF gas delivered into a heated, low-pressure chamber. A controlled flow of an alcohol vapor, typically ethanol, is added to act as a catalyst and a source of water for the reaction. The HF and ethanol react on the wafer surface to form a thin layer of diluted hydrofluoric acid that etches silicon dioxide, while the volatile byproducts are pumped away.

Where it fits in the process flow

General reference — not yet source-verified

Vapor HF etch tools are used after silicon dioxide deposition steps or before critical release processes in MEMS fabrication. The tool fits in a fab's etch module where dry, isotropic oxide removal is needed without introducing moisture or particle contamination.

Applications

General reference — not yet source-verified

The primary application of vapor HF etching is the release of microelectromechanical systems (MEMS) structures, such as accelerometers, gyroscopes, and pressure sensors. The dry process eliminates stiction caused by capillary forces in liquid etching.

Other applications include the removal of sacrificial oxide layers in advanced packaging, cleaning of oxide residues after plasma etching, and selective oxide removal in front-end-of-line processes where damage to active layers must be minimized.

What do the numbers mean?

Vacuum & pumping2

Pressure
50-250 Torr[1]
Accurate?
Pressure Range
50–250 Torr[1]
Accurate?

Wafer handling1

Wafer Size
8 inch[1]
Accurate?

Gas & chemistry2

HF Flow Rates
50 sccm-1000 sccm[1]
Accurate?
HF Flow Rate
50–1000 sccm[1]
Accurate?

Configuration & options4

Temperature
35 C to 70 C[1]
Accurate?
Ethanol Flow Rates
0.1 to 1 ml/min[1]
Accurate?
Temperature Range
35°C to 70°C[1]
Accurate?
Ethanol Flow Rate
0.1–1 ml/min[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Pressure50-250 Torr[1]
  • HF Flow Rates50 sccm-1000 sccm[1]
  • Pressure Range50–250 Torr[1]
  • HF Flow Rate50–1000 sccm[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What wafer sizes does the SPTS Monarch support?

The SPTS Monarch supports 200 mm (8-inch) wafers.[1]

What HF flow rates are supported?

HF flow rates range from 50 sccm to 1000 sccm.[1]

What ethanol flow rates are supported?

Ethanol flow rates range from 0.1 ml/min to 1 ml/min.[1]

Not publicly documented

The following facts about the Monarch Hydrofluoric (HF) Vapor are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the Monarch Hydrofluoric (HF) Vapor are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the Monarch Hydrofluoric (HF) Vapor are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the Monarch Hydrofluoric (HF) Vapor are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Monarch Hydrofluoric (HF) Vapor are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Monarch Hydrofluoric (HF) Vapor is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (1)Every fact above is drawn from these public sources
  1. [1]Inventory photo
Was this page accurate?

Last updated Sep 24, 2026.

Compare with similar tools