Thermo Fisher

Orbitrap Velos Pro

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Thermo Fisher Orbitrap Velos Pro is a hybrid mass spectrometer. The Thermo Fisher Orbitrap Velos Pro combines a Velos Pro dual-cell linear trap with an Orbitrap analyzer. The Thermo Fisher Orbitrap Velos Pro ETD mass spectrometer adds a reagent ion source for Electron Transfer Dissociation analyses.[1]

Orbitrap Velos Pro — Inventory photo
Fig. 01Orbitrap Velos ProInventory photo[3]

What it is

The Thermo Fisher Orbitrap Velos Pro is a hybrid mass spectrometer that combines a linear ion trap with an Orbitrap mass analyzer. The instrument belongs to the LTQ family of hybrid mass spectrometers.[1]

How it works

The Orbitrap Velos Pro hardware includes a dual-pressure linear ion trap, an Orbitrap mass analyzer, transfer optics, a C-Trap, and a collision cell for higher-energy collisional dissociation. The instrument supports CID, HCD, and optionally ETD fragmentation.[5][1]

Where it fits in the process flow

General reference — not yet source-verified

The Orbitrap Velos Pro sits in an analytical measurement workflow after sample preparation and ionization. The instrument receives ions from an external source and performs mass analysis on the resulting ion population.

What do the numbers mean?

Power & electrical1

Power
230 Vac ± 10% 3 phase, 15 Ampere, 50/60 Hz, with earth ground for the instrument[5]
Accurate?

Gas & chemistry2

Helium gas
Ultra-high purity (99.999%) with less than 1 ppm each of water, oxygen and total hydrocarbons[5]
Accurate?
Nitrogen gas
High purity (99.5% pure, flow rate 15 L/min) nitrogen gas supply for the API source and the C-Trap[5]
Accurate?

Optics & imaging4

Instrument type
Hybrid high-resolution accurate-mass mass spectrometer[4]
Accurate?
Resolution
Up to 60,000 (FWHM) at m/z 400[4]
Accurate?
Resolution
60000 (FWHM) @ m/z 400 with a scan repetition rate of 1 second; minimum resolution 7500; maximum resolution 100000 @ m/z 400[1]
Accurate?
Cycle time
1 scan at 60000 resolution @ m/z 400 per second[1]
Accurate?

Performance2

Mass accuracy
Better than 1 ppm RMS using internal calibration[5]
Accurate?
Mass accuracy
<3 ppm RMS for 2 h period with external calibration using defined conditions; <1 ppm RMS with internal calibration[1]
Accurate?

Dimensions & facilities2

Weight
MS: ~ 620 kg[5]
Accurate?
Dimensions
MS with ETD: 142 cm x 87 cm x 171 cm; MS without ETD: 142 cm x 87 cm x 142 cm[5]
Accurate?

Configuration & options9

OEM
Thermo Fisher[3]
Accurate?
Model
Orbitrap Velos Pro[3]
Accurate?
Mass analyzer configuration
Dual-cell linear ion trap coupled with electrostatic orbital trap (Orbitrap)[4]
Accurate?
Fragmentation techniques
CID, HCD, and optionally ETD[5]
Accurate?
Mass range
m/z 50-2,000; m/z 200-4,000[5]2 sources
Accurate?
Polarity
Positive/Negative switching within single run[4]
Accurate?
Release year of hardware manual
2011[1]
Accurate?
Dynamic range
>10000 between mass spectra; >5000 between highest and lowest detectable ion signal in one spectrum[1]
Accurate?
MS/MS
MS/MS and MSn scan functions[1]
Accurate?

Vintage & configurations

  1. 2011-06Manual release[1]

    Revision A of the Orbitrap Velos Pro Hardware Manual was released in June 2011.

  2. 2013-04Manual release[2]

    Revision A of the Orbitrap Velos Pro Getting Started manual was released in April 2013.

Documented models & variants

DesignationGenerationVintageChangesSource
Orbitrap Velos Pro ETD—2011ETD Module is physically coupled to the back of the Orbitrap Velos Pro mass spectrometer.documents.thermofisher.com[1]
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power230 Vac ± 10% 3 phase, 15 Ampere, 50/60 Hz, with earth ground for the instrument[5]
  • Helium gasUltra-high purity (99.999%) with less than 1 ppm each of water, oxygen and total hydrocarbons[5]
  • Nitrogen gasHigh purity (99.5% pure, flow rate 15 L/min) nitrogen gas supply for the API source and the C-Trap[5]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the mass range of the Orbitrap Velos Pro?

The mass range is m/z 50–2,000 and m/z 200–4,000.[5]

What resolution can the instrument achieve?

The resolution is 60,000 at m/z 400 at a scan rate of 1 Hz, with a minimum resolution of 7,500 and a maximum resolution greater than 100,000 at m/z 400.[5]

What mass accuracy does the Orbitrap Velos Pro provide?

Mass accuracy is less than 3 ppm RMS with external calibration and less than 1 ppm RMS using internal calibration.[5]

What is the sensitivity specification for MS/MS?

Using electrospray ionization, injection of 2 μL of a 50 fg/μL solution of reserpine (100 femtograms total) at 500 μL/min produces a minimum signal-to-noise ratio of 100:1 for the transition of m/z 609 to m/z 397 and m/z 448 when operating at unit resolution in full-scan MS/MS mode.[5]

What is the dynamic range of the instrument?

The dynamic range is greater than 5,000 within a single scan, guaranteeing specified mass accuracy.[5]

What fragmentation techniques are available?

The instrument supports CID, HCD, and optionally ETD. The HCD collision cell includes an axial field gradient for improved efficiency.[5]

Not publicly documented

The following facts about the Orbitrap Velos Pro are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • The control-system platform and OS era of the Orbitrap Velos Pro are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the Orbitrap Velos Pro are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the Orbitrap Velos Pro is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

  • No publicly documented compatible parts, consumables, or accessories for the Orbitrap Velos Pro are on record.

    Answerable by: an OEM parts catalog or a service engineer

  • No publicly hosted manuals, SOPs, or datasheets for the Orbitrap Velos Pro are on record.

    Answerable by: university cleanroom staff or an OEM application specialist

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (5)Every fact above is drawn from these public sources
  1. [1]documents.thermofisher.com — documents.thermofisher.comdocuments.thermofisher.com