Waferpedia

Thermotron

SE 600 15 15 Temperature

Thermotron SE 600 15 15 Temperature family
Research Quality: 30% complete

Provisional entry — research in progress

This page was generated automatically from cited public sources and hasn't completed the full research pass yet. Every specification shown carries its source; more detail is added as research completes.

The Thermotron SE 600 15 15 is a fast ramp temperature and humidity climate chamber. The SE 600 15 15 has a temperature range of -70°C to 180°C. The SE 600 15 15 offers a humidity range of 10% to 98% RH.[1][2]

ThermotronSE 600 15 15 Temperature
No photo available yet

Power

460V, 3PH, 70 Amps[1]

Performance

±0.5°C (±0.9°F)[2]

What it is

The Thermotron SE 600 15 15 is a temperature chamber.[3]

The Thermotron SE-600-15-15 is an environmental chamber used for temperature and humidity testing.[1]

What do the numbers mean?

Power & electrical2

Electrical Requirements
460V, 3PH, 70 Amps[1]
Accurate?
Power
460 V, 3 PH, 70 A[1]
Accurate?

Performance1

Temperature Uniformity
±0.5°C (±0.9°F)[2]
Accurate?

Control & software2

Temperature Control Tolerance
0.3°C (0.5°F)[2]
Accurate?
Humidity Control
±2.5% RH[2]
Accurate?

Dimensions & facilities5

Workspace Dimensions (W x D x H)
40 x 26.25 x 34 inches (102 x 67 x 86 cm)[2]
Accurate?
Approx. Shipping Weight
2,115 lbs (959 kg)[2]
Accurate?
Move-In Dimensions (W x D x H)
49 x 70 x 83 inches (124 x 178 x 211 cm)[2]
Accurate?
Interior dimensions
40 in W x 26 in D x 34 in H[1]
Accurate?
Outer dimensions
49 in W x 70 in D x 83 in H[1]
Accurate?

Configuration & options14

Workspace Volume
20.7 ft³ (586 L)[2]
Accurate?
Temperature Range
-70°C to 180°C (-94°F to 356°F)[2]
Accurate?
Humidity Range
10% to 98% RH[2]
Accurate?
Heating Performance (rate -65° to 71°C)
19°C per minute[1]
Accurate?
Cooling Performance (rate 71° to -65°C)
10.4°C per minute[1]
Accurate?
Heating Performance in Minutes (-65° to 71°C)
11 minutes[2]
Accurate?
Heating Performance in °C/Minute (-65° to 71°C)
19.4°C[2]
Accurate?
Cooling Performance in Minutes (71° to -65°C)
22 minutes[2]
Accurate?
Cooling Performance in °C/Minute (71° to -65°C)
10.4°C[2]
Accurate?
Model
SE-600-15-15[1]
Accurate?
Type
Temperature chamber[3]
Accurate?
Type
Fast ramp chamber[1]
Accurate?
Type
Temperature humidity climate chamber[1]
Accurate?
Temperature range
-70 to +180 °C[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Electrical Requirements460V, 3PH, 70 Amps[1]
  • Power460 V, 3 PH, 70 A[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What are the heating and cooling rates of the chamber?

The heating rate is 19.4 degrees Celsius per minute from -65 to 71 degrees Celsius. The cooling rate is 10.4 degrees Celsius per minute from 71 to -65 degrees Celsius.[1][2]

What type of controller does the chamber use?

The chamber uses a Thermotron Model 8800 touchscreen programmer with temperature limit control.[1]

What are the electrical power requirements for the chamber?

The chamber requires 460 volts, 3-phase, 70 amps. The full load amps at 460/3/60 is 55 amps, at 400/3/50 is 59 amps, at 230/3/60 is 110 amps, and at 208/3/60 is 122 amps.[1][2]

Not publicly documented

The following facts about the SE 600 15 15 Temperature are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the SE 600 15 15 Temperature are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the SE 600 15 15 Temperature are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the SE 600 15 15 Temperature are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the SE 600 15 15 Temperature are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the SE 600 15 15 Temperature is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (3)Every fact above is drawn from these public sources
  1. [1]lre.com — lre.comlre.com
  2. [2]lre.com — lre.comlre.com
  3. [3]Equipment inventory listing
Was this page accurate?

Last updated Oct 7, 2026.

Compare with similar tools

View all →