Waferpedia

Comparison ledger

0010-22161 High EFF RF MatchversusDuo 3 Vacuum

Applied Materials 0010-22161 High EFF RF Match, Pfeiffer Duo 3 Vacuum, side by side. Every value shown is drawn from the cited encyclopedia entries.

Side-by-side comparison of selected equipment models
Attribute
Duo 3 VacuumPfeiffer
OEMApplied MaterialsPfeiffer
Category——
Wafer size——
Process node——
Introduced——
Production run——
Lifecycle——
Lifecycle milestones——
Control system——
Generation——
FamilyApplied Materials 0010-22161 High EFF RF MatchPfeiffer Duo 3 Vacuum
Cited variants—
Specifications
MakeApplied Materials[2]—
Model0010-22161[2]Duo 3[6]
DescriptionHTESC PH 1 REV A[3]—
ConditionUsed[3]—
Stock NumberBM6628[3]—
Pump type—Rotary vane pump[4]
Construction—Oil-sealed rotational displacement pump[4]
Stage—Dual-stage[5]
Variants—Duo 3 standard version, Duo 3 M, Duo 3 MC[1]
Duo 3 M difference—Magnetic coupling[1]
Duo 3 MC differences—Operating fluid F4; magnetic coupling encapsulated on the pump side; vane material changed; hose connection on the gas ballast valve; leakage rate ≤ 1 × 10-8 Pa m3/s[1]
Gas ballast / safety valve—Integrated gas ballast and safety valve[5]
Pumping speed at 50 Hz—2.5 m3/h[5]
Pumping speed at 60 Hz—2.9 m3/h[5]
Ultimate pressure with gas ballast—3 × 10-3 hPa[5]
Ultimate pressure without gas ballast—3 × 10-3 hPa[5]
Exhaust pressure, max.—1,500 hPa[5]
Rotation speed at 50 Hz—3,000 rpm[5]
Rotation speed at 60 Hz—3,600 rpm[5]
Cooling method—Air[5]
Motor version—1-ph motor[5]
Ambient temperature—12-40 °C[5]
Emission sound pressure level without gas ballast at 50 Hz—53 dB(A)[5]
Mains requirement voltage 50 Hz—230-240 V[5]
Mains requirement voltage 60 Hz—230-240 V[5]
Recommended mains fuse capacity—4 A[5]
Operating fluid—P3[5]
Operating fluid filling—0.4 l[5]
Leak rate safety valve—1 × 10-5 Pa m3/s[5]
Dimensions—309 x 129 x 222 mm[5]
Rated power 50 Hz—0.15 kW[5]
Rated power 60 Hz—0.18 kW[5]
Protection category—IP40[5]
Weight—11.3 kg[5]
Manufacturer—Pfeiffer[6]
Pump construction—Oil-sealed[1]
Stages—Two-stage[1]
Application range—Coarse and medium vacuum[1]
Variants stated—Standard version, M version, MC version[1]
MC version changes—Operating fluid F4, magnetic coupling encapsulated on the pump side, changed vane material, hose connection on the gas ballast valve, leakage rate ≤ 1 × 10-8 Pa m3/s[1]
Sources (6)Every fact above is drawn from these public sources
  1. [1]pfeiffervacuum.compfeiffervacuum.com
  2. [2]Equipment inventory listing
  3. [3]tarasemi.comtarasemi.com
  4. [4]manualslib.commanualslib.com
  5. [5]ajvs.comajvs.com
  6. [6]Equipment inventory listing