What it is

The Seiko Epson WAM 5500 is a binocular accommodation auto refractometer/keratometer, an ophthalmic instrument designed to measure refractive error and corneal curvature. The instrument allows the patient to maintain natural binocular vision during measurement, which helps eliminate instrument-induced accommodation and provides accurate refraction examination.[1]

The WAM 5500 is also equipped with functions that enable the measurement of far and near distance refractive power as well as the simultaneous measurement of pupil diameter. The instrument is marketed under the Seiko Epson brand and is manufactured by Rexxam Co., Ltd., a Japanese ophthalmic device OEM.[1][2]

How it works

The WAM 5500 measures refraction using a binocular viewfinder that presents a fixation target to the patient while the instrument captures spherical (S), cylindrical (C), and axis (A) values. The refractive measurement range is -22 D to +22 D with selectable steps of 0.01 D, 0.12 D, and 0.25 D. Corneal curvature radius is measured from 5.0 mm to 10.0 mm, corresponding to corneal refractive powers of 33.75 D to 67.5 D. The instrument can also measure pupil diameter in a range of 2.0 mm to 8.0 mm with 0.1 mm steps.[1]

The instrument features a high-speed mode that, when connected to a computer, can continuously measure the spherical equivalent (SE) value and pupil diameter at 0.2-second intervals. An accommodation mode allows simultaneous measurement of pupil diameter and refractive value, enabling assessment of miosis and mydriasis occurring with accommodation. The measurement time for refractive measurement is approximately 0.07 seconds, for pupil diameter approximately 0.07 seconds, and for corneal curvature radius approximately 2.2 seconds.[1]

What do the numbers mean?

Power & electrical1

Power Supply
AC 100 - 240 V, 50/60 Hz, 80 VA[1]
Accurate?

Control & software2

Continuous Measurement Interval
0.2 seconds (when connected to PC)[1]
Accurate?
Data Output Interface
RS-232C[1]
Accurate?

Dimensions & facilities2

Dimensions (W × D × H)
327 mm × 496 mm × 515 mm[1]
Accurate?
Weight
approx. 20 kg[1]
Accurate?

Configuration & options13

Refractive Measurement Range (Sphere)
-22D ~ +22D (VD=0)[1]
Accurate?
Cylinder Measurement Range
0D ~ ±10D (VD=0)[1]
Accurate?
Axis Measurement Range
0° ~ 180°, step 1°[1]
Accurate?
Minimum Pupil Diameter Measurable
Ф2.3 mm[1]
Accurate?
Corneal Curvature Radius Measurement Range
5.0 mm ~ 10.0 mm[1]
Accurate?
Corneal Refractivity Range
33.75D ~ 67.5D (n=1.3375)[1]
Accurate?
Degree of Corneal Astigmatism Range
0D ~ ±9D[1]
Accurate?
Pupil Diameter Measurement Range
Ф2.0 ~ 8.0 mm, step 0.1 mm[1]
Accurate?
PD Measurement Range
85 mm, step 1 mm[1]
Accurate?
Measurement Time (Refractive)
approx. 0.07 second[1]
Accurate?
Measurement Time (Pupil Diameter)
approx. 0.07 second[1]
Accurate?
Measurement Time (Corneal Curvature Radius)
approx. 2.2 seconds[1]
Accurate?
Monitor
5.7 inch color LCD[1]
Accurate?
Interested in this tool?
Need help with this tool?Embed spec card

What does it need to run?

Site utility requirements, footprint, and infrastructure needed to install and operate this tool. Sourced from public records.

  • Power SupplyAC 100 - 240 V, 50/60 Hz, 80 VA[1]

Where are the manuals?

Generated from public-source data on file. Enter your email to access — nothing is published; details are routed privately.

Not publicly documented

Field notes

No research found yet — worked with this tool? Share what you know.

Worked with this tool? Help preserve its knowledge →

Frequently asked questions

What is the refractive measurement range of the WAM 5500?

The refractive measurement range is -22 D to +22 D (VD=0) with selectable steps of 0.01 D, 0.12 D, and 0.25 D.[1]

What are the dimensions and weight of the WAM 5500?

The dimensions are 327 mm (W) × 496 mm (D) × 515 mm (H), and the weight is approximately 20 kg.[1]

Does the WAM 5500 measure pupil diameter simultaneously with refraction?

Yes, the WAM 5500 can measure pupil diameter simultaneously with the refractive value, with a measurement range of 2.0 mm to 8.0 mm and a step of 0.1 mm.[1]

What is the continuous measurement interval in high-speed mode?

In high-speed mode, the spherical equivalent (SE) value and pupil diameter are measured at 0.2-second intervals when connected to a computer.[1]

What measurement interfaces does the WAM 5500 support?

The instrument provides an RS-232C interface for data output.[1]

What is the power requirement of the WAM 5500?

The power requirement is AC 100–240 V, 50/60 Hz, with a maximum power consumption of 80 VA.[1]

Not publicly documented

The following facts about the WAM 5500 are absent from this record as of this revision. First-hand knowledge or a citation closes a gap; every submission is reviewed before publication.

  • No publicly documented production dates or lifecycle milestones (introduction, end of production, EOL) for the WAM 5500 are on record.

    Answerable by: OEM historical records or a trade-press announcement

  • No publicly documented variants, configuration options, or revision breakpoints of the WAM 5500 are on record.

    Answerable by: an OEM product catalog or an engineer who ordered or specified the tool

  • The control-system platform and OS era of the WAM 5500 are not on record.

    Answerable by: an engineer who operated it or OEM installation records

  • No publicly documented failure modes or field errata for the WAM 5500 are on record.

    Answerable by: a field service engineer, process engineer, or maintenance technician

  • The process node or technology generation of the WAM 5500 is not on record.

    Answerable by: an OEM datasheet or a fab qualification report

No research found yet — worked with this tool? Share what you know.

Sources & citations

Sources (2)Every fact above is drawn from these public sources
  1. [1]rexxam.co.jp — rexxam.co.jprexxam.co.jp
  2. [2]Equipment inventory listing
Was this page accurate?

Last updated Sep 26, 2026.

Compare with similar tools

View all →